CITY WIDE HOME INSPECTORS
InterNACHI Standards of
Practice
Table of Contents
1. Definitions and Scope.
2. Standards of Practice
2.1. Roof
2.2. Exterior
2.3. Basement, Foundation, Crawlspace & Structure
2.4. Heating
2.5. Cooling
2.6. Plumbing
2.7. Electrical
2.8. Fireplace
2.9. Attic & Insulation
2.10. Doors, Windows & Interior
3. Limitations, Exceptions & Exclusions
4. Glossary of Terms
1. Definitions and Scope
1.1. A Home Inspection is a non-invasive visual examination of a
residential dwelling, performed for a fee, which is designed to
identify observed material defects within specific components of
said dwelling. Components may include any combination of
mechanical, structural, electrical, plumbing, or other essential
systems or portions of the home, as identified and agreed to by the
Client and Inspector, prior to the inspection process.
I. A Home Inspection is intended to assist in evaluation of the
overall condition of the dwelling. The inspection is based on
observation of the visible and apparent condition of the structure
and its components on the date of the inspection and not
the prediction of future conditions.
II. A home inspection will not reveal every concern that exists or
ever could exist, but only those material defects observed on the
day of the inspection.
1.2. A Material Defect is a condition of a residential real property
or any portion of it that would have a significant adverse impact on
the value of the real property or that involves an unreasonable risk
to people on the property. The fact that a structural element,
system or subsystem is near, at or beyond the end of the normal
useful life of such a structural element, system or subsystem is not
by itself a material defect.
1.3. An Inspection report shall describe and identify in written
format the inspected systems, structures, and components of the
dwelling and shall identify material defects observed. Inspection
reports may contain recommendations regarding conditions reported or
recommendations for correction, monitoring or further evaluation by
professionals, but this is not required.
2. Standards of Practice
2.1. Roof
I. The inspector shall inspect from ground level or eaves:
A. The roof covering.
B. The gutters.
C. The downspouts.
D. The vents, flashings, skylights, chimney and other roof
penetrations.
E. The general structure of the roof from the readily accessible
panels, doors or stairs.
II. The inspector is not required to:
A. Walk on any pitched roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter drainage pipes.
D. Remove snow, ice, debris or other conditions that prohibit the
observation of the roof surfaces.
E. Move insulation.
F. Inspect antennae, lightning arresters, de-icing equipment, or
similar attachments.
G. Walk on any roof areas that appear, in the opinion of the
inspector, to be unsafe.
H. Walk on any roof areas if it might, in the opinion of the
inspector, cause damage.
I. Perform a water test.
J. Warrant or certify the roof.
2.2. Exterior
I. The inspector shall inspect:
A. The siding, flashing and trim.
B. All exterior doors, decks, stoops, steps, stairs, porches,
railings, eaves, soffits and fascias.
C. And report as in need of repair any spacings between intermediate
balusters, spindles, or rails for steps, stairways, balconies, and
railings that permit the passage of an object greater than four
inches in diameter.
D. A representative number of windows.
E. The vegetation, surface drainage and retaining walls when these
are likely to adversely affect the structure.
F. And describe the exterior wall covering.
II. The inspector is not required to:
A. Inspect or operate screens, storm windows, shutters, awnings,
fences, outbuildings, or exterior accent lighting.
B. Inspect items, including window and door flashings, which are not
visible or readily accessible from the ground.
C. Inspect geological, geotechnical, hydrological and/or soil
conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and docks.
F. Inspect erosion control and earth stabilization measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
I. Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal window seals or damaged
glass.
2.3. Basement, Foundation & Crawlspace
I. The inspector shall inspect:
A. The basement.
B. The foundation
C. The crawlspace.
D. The visible structural components.
E. And report on the location of under-floor access openings.
F. And report any present conditions or clear indications of active
water penetration observed by the inspector.
G. For wood in contact or near soil.
H. And report any general indications of foundation movement that
are observed by the inspector, such as but not limited to sheetrock
cracks, brick cracks, out-of-square door frames or floor slopes.
I. And report on any cutting, notching and boring of framing members
which may present a structural or safety concern.
II. The inspector is not required to:
A. Enter any crawlspaces that are not readily accessible or where
entry could cause damage or pose a hazard to the inspector.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible floats.
D. Identify size, spacing, span, location or determine adequacy of
foundation bolting, bracing, joists, joist spans or support systems.
E. Provide any engineering or architectural service.
F. Report on the adequacy of any structural system or component.
2.4. Heating
I. The inspector shall inspect:
A. The heating systems using normal operating controls and describe
the energy source and heating method.
B. And report as in need of repair heating systems which do not
operate.
C. And report if the heating systems are deemed inaccessible
II. The inspector is not required to:
A. Inspect or evaluate interiors of flues or chimneys, fire
chambers, heat exchangers, humidifiers, dehumidifiers, electronic
air filters, solar heating systems or fuel tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity, temperature, flow, balance,
distribution, size, capacity, BTU, or supply adequacy of the heating
system.
D. Light or ignite pilot flames.
E. Activate heating, heat pump systems, or other heating systems
when ambient temperatures or when other circumstances are not
conducive to safe operation or may damage the equipment.
F. Override electronic thermostats.
G. Evaluate fuel quality.
H. Verify thermostat calibration, heat anticipation or automatic
setbacks, timers, programs or clocks.
2.5. Cooling
I. The inspector shall inspect:
A. The central cooling equipment using normal operating controls.
II. The inspector is not required to:
A. Determine the uniformity, temperature, flow, balance,
distribution, size, capacity, BTU, or supply adequacy of the cooling
system.
B. Inspect window units, through-wall units, or electronic air
filters.
C. Operate equipment or systems if exterior temperature is below 60
degrees Fahrenheit or when other circumstances are not conducive to
safe operation or may damage the equipment.
D. Inspect or determine thermostat calibration, heat anticipation or
automatic setbacks or clocks.
E. Examine electrical current, coolant fluids or gases, or coolant
leakage.
2.6. Plumbing
I. The inspector shall:
A. Verify the presence of and identify the location of the main
water shutoff valve.
B. Inspect the water heating equipment, including combustion air,
venting, connections, energy sources, seismic bracing, and verify
the presence or absence of temperature-pressure relief valves and/or
Watts 210 valves.
C. Flush toilets.
D. Run water in sinks, tubs, and showers.
E. Inspect the interior water supply including all fixtures and
faucets.
F. Inspect the drain, waste and vent systems, including all
fixtures.
G. Describe any visible fuel storage systems.
H. Inspect the drainage sump pumps and test pumps with accessible
floats.
I. Inspect and describe the water supply, drain, waste and main fuel
shut-off valves, as well as the location of the water main and main
fuel shut-off valves.
J. Inspect and determine if the water supply is public or private.
K. Inspect and report as in need of repair deficiencies in the water
supply by viewing the functional flow in two fixtures operated
simultaneously.
L. Inspect and report as in need of repair deficiencies in
installation and identification of hot and cold faucets.
M. Inspect and report as in need of repair mechanical drain-stops
that are missing or do not operate if installed in sinks, lavatories
and tubs.
N. Inspect and report as in need of repair commodes that have cracks
in the ceramic material, are improperly mounted on the floor, leak,
or have tank components which do not operate.
II. The inspector is not required to:
A. Light or ignite pilot flames.
B. Determine the size, temperature, age, life expectancy or adequacy
of the water heater.
C. Inspect interiors of flues or chimneys, water softening or
filtering systems, well pumps or tanks, safety or shut-of valves,
floor drains, lawn sprinkler systems or fire sprinkler systems.
D. Determine the exact flow rate, volume, pressure, temperature, or
adequacy of the water supply.
E. Determine the water quality or potability or the reliability of
the water supply or source.
F. Open sealed plumbing access panels.
G. Inspect clothes washing machines or their connections.
H. Operate any main, branch or fixture valve.
I. Test shower pans, tub and shower surrounds or enclosures for
leakage.
J. Evaluate the compliance with local or state conservation or
energy standards, or the proper design or sizing of any water, waste
or venting components, fixtures or piping.
K. Determine the effectiveness of anti-siphon, back-flow prevention
or drain-stop devices.
L. Determine whether there are sufficient clean-outs for effective
cleaning of drains.
M. Evaluate gas, liquid propane or oil storage tanks.
N. Inspect any private sewage waste disposal system or component of.
O. Inspect water treatment systems or water filters.
P. Inspect water storage tanks, pressure pumps or bladder tanks.
Q. Evaluate wait time to obtain hot water at fixtures, or perform
testing of any kind to water heater elements.
R. Evaluate or determine the adequacy of combustion air.
S. Test, operate, open or close safety controls, manual stop
valves and/or temperature or pressure relief valves.
T. Examine ancillary systems or components, such as, but not limited
to, those relating to solar water heating, hot water circulation.
U. Determine the existence or condition of polybutylene plumbing.
2.7. Electrical
I. The inspector shall inspect:
A. The service drop/lateral.
B. The meter socket enclosures.
C. The means for disconnecting the service main.
D. And determine the rating of the service amperage.
E. Panelboards and overcurrent devices (breakers and fuses).
F. And report on any unused circuit breaker panel openings that are
not filled.
G. The service grounding and bonding.
H. A representative number of switches, receptacles, lighting
fixtures, AFCI protected receptacles.
I. And test all Ground Fault Circuit Interrupter (GFCI) receptacles
and GFCI circuit breakers observed and deemed to be GFCI's during
the inspection using a GFCI tester.
J. And report the presence of solid conductor
aluminum branch circuit wiring if readily visible.
K. And report on any tested GFCI-tested receptacles in which
power was not present, polarity is incorrect, is not secured to the
wall, the cover is not in place, the ground fault circuit
interrupter devices are not properly installed or do not operate
properly, evidence of arcing or excessive heat is present, or where
the receptacle is not grounded or is not secured to the wall.
L. The service entrance conductors and
the condition of the conductor insulation.
M. And describe the amperage rating of the service.
N. And report the absence of smoke detectors.
O. Service entrance cables and report as in need of repair
deficiencies in the integrity of the insulation, drip loop, or
separation of conductors at weatherheads and clearances from grade
or rooftops.
II. The inspector is not required to:
A. Insert any tool, probe or device into the main panelboard,
sub-panels, distribution panelboards, or electrical fixtures.
B. Operate electrical systems that are shut down.
C. Remove panelboard cabinet covers or dead front covers if they are
not readily accessible.
D. Operate overcurrent protection devices.
E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or voltage of the main service
equipment if not visibly labeled.
G. Inspect the fire or alarm system and components.
H. Inspect the ancillary wiring or remote control devices.
I. Activate any electrical systems or branch circuits which are not
energized.
J. Operate or reset overload devices.
K. Inspect low voltage systems, electrical de-icing tapes, swimming
pool wiring or any time-controlled devices.
L. Verify the service ground.
M. Inspect private or emergency electrical supply sources, including
but not limited to generators, windmills, photovoltaic solar
collectors, or battery or electrical storage facility.
N. Inspect spark or lightning arrestors.
O. Inspect or test de-icing equipment.
P. Conduct voltage drop calculations.
Q. Determine the accuracy of labeling.
2.8. Fireplace
I. The inspector shall inspect:
A. The fireplace, and open and close the damper door if readily
accessible and operable.
B. Hearth extensions and other permanently installed components.
C. And report as in need of repair deficiencies in the lintel,
hearth and material surrounding the fireplace, including clearance
from combustible materials
II. The inspector is not required to:
A. Inspect the flue or vent system.
B. Inspect the interior of chimneys or flues, fire doors or screens,
seals or gaskets, or mantels.
C. Determine the need for a chimney sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of any installation.
G. Inspect automatic fuel feed devices.
H. Inspect combustion and/or make-up air devices.
I. Inspect heat distribution assists whether gravity controlled or
fan assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves, or firebox contents.
M. Determine adequacy of draft, perform a smoke test or dismantle or
remove any component.
N. Perform a National Fire Prevention Association (NFPA)
style inspection.
2.9. Attic, Ventilation & Insulation
I. The inspector shall inspect:
A. The insulation in unfinished spaces.
B. The ventilation of attic spaces.
C. Mechanical ventilation systems.
D. And report on the general absence or lack of insulation.
II. The inspector is not required to:
A. Enter the attic or any unfinished spaces that are not readily
accessible or where entry could cause damage or pose a safety hazard
to the inspector in his or her opinion.
B. To move, touch, or disturb insulation.
C. To move, touch or disturb vapor retarders.
D. Break or otherwise damage the surface finish or weather seal on
or around access panels and covers.
E. Identify the composition or exact R-value of insulation material.
F. Activate thermostatically operated fans.
G. Determine the types of materials used in insulation or wrapping
of pipes, ducts, jackets, boilers, and wiring.
H. Determine the adequacy of ventilation.
2.10. Doors, Windows & Interior
I. The inspector shall:
A. Open and close a representative number of doors and windows.
B. Inspect the walls, ceilings, steps, stairways, and railings.
C. And report as in need of repair any spacing between intermediate
balusters, spindles, or rails for steps, stairways, and railings
that permits the passage of an object greater than four inches in
diameter.
D. Inspect garage doors and garage door openers by operating first
by remote (if available) and then by the installed automatic door
control.
E. And report as in need of repair any installed electronic sensors
that are not operable or not installed at proper heights above the
garage door.
F. And report as in need of repair any door locks or side ropes that
have not been removed or disabled when garage door opener is in use.
G. And report as in need of repair any windows that are obviously
fogged or display other evidence of broken seals.
II. The inspector is not required to:
A. Inspect paint, wallpaper, window treatments or finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing.
D. Inspect security systems or components.
E. Evaluate the fastening of countertops, cabinets, sink tops and
fixtures, or firewall compromises.
F. Move furniture, stored items, or any coverings like carpets or
rugs in order to inspect the concealed floor structure.
G. Move drop ceiling tiles.
H. Inspect or move any household appliances..
I. Inspect or operate equipment housed in the garage except as
otherwise noted.
J. Verify or certify safe operation of any auto reverse or related
safety function of a garage door.
K. Operate or evaluate any security bar release and opening
mechanisms, whether interior or exterior, including their compliance
with local, state, or federal standards.
L. Operate any system, appliance or component that requires the use
of special keys, codes, combinations, or devices.
M. Operate or evaluate self-cleaning oven cycles, tilt
guards/latches or signal lights.
N. Inspect microwave ovens or test leakage from microwave ovens.
O. Operate or examine any sauna, steam-jenny, kiln, toaster,
ice-maker, coffee-maker, can-opener, bread-warmer, blender, instant
hot water dispenser, or other small, ancillary devices.
P. Inspect elevators.
Q. Inspect remote controls.
R. Inspect appliances.
S. Inspect items not permanently installed.
T. Examine or operate any above-ground, movable, freestanding, or
otherwise non-permanently installed pool/spa, recreational
equipment or self-contained equipment.
U. Come into contact with any pool or spa water in order to
determine the system structure or components.
V. Determine the adequacy of spa jet water force or bubble effect.
W. Determine the structural integrity or leakage of a pool or spa.
3. Limitations, Exceptions & Exclusions
3.1. Limitations:
I. An inspection is not technically exhaustive.
II. An inspection will not identify concealed or latent defects.
III. An inspection will not deal with aesthetic concerns or what
could be deemed matters of taste, cosmetic defects, etc.
IV. An inspection will not determine the suitability of the property
for any use.
V. An inspection does not determine the market value of the property
or its marketability.
VI. An inspection does not determine the insurability of the
property.
VI. An inspection does not determine the advisability or
inadvisability of the purchase of the inspected property.
VIII. An inspection does not determine the life expectancy of the
property or any components or systems therein.
IX. An inspection does not include items not permanently installed.
X. These Standards of Practice apply only to homes with four or
fewer dwelling units.
3.2. Exclusions:
I. The inspectors are not required to determine:
A. Property boundary lines or encroachments.
B. The condition of any component or system that is not readily
accessible.
C. The service life expectancy of any component or system.
D. The size, capacity, BTU, performance, or efficiency of any
component or system.
E. The cause or reason of any condition.
F. The cause for the need of repair or replacement of any system or
component.
G. Future conditions.
H. Compliance with codes or regulations.
I. The presence of evidence of rodents, animals or insects.
J. The presence of mold, mildew or fungus.
K. The presence of air-borne hazards.
L. The presence of birds.
M. The presence of other flora or fauna.
N. The air quality.
O. The existence of asbestos.
P. The existence of environmental hazards.
Q. The existence of electro-magnetic fields.
R. The presence of hazardous materials including, but not limited
to, the presence of lead in paint.
S. Any hazardous waste conditions.
T. Any manufacturer's recalls or conformance with manufacturer
installation or any information included for consumer protection
purposes.
U. Operating costs of systems.
V. Replacement or repair cost estimates.
W. The acoustical properties of any systems.
X. Estimates of the cost to operating any given system.
II. The inspectors are not required to operate:
A. Any system that is shut down.
B. Any system that does not function properly.
C. Or evaluate low voltage electrical systems such as, but not
limited to:
1. Phone lines.
2. Cable lines.
3. Antennae.
4. Lights.
5. Remote controls.
D. Any system that does not turn on with the use of normal operating
controls.
E. Any shut off valves or manual stop valves.
F. Any electrical disconnect or over current protection devices.
G. Any alarm systems.
H. Moisture meters, gas detectors or similar equipment.
III. The inspectors are not required to:
A. Move any personal items or other obstructions, such as, but not
limited to:
1. Throw rugs.
2. Furniture.
3. Floor or wall coverings.
4. Ceiling tiles
5. Window coverings.
6. Equipment.
7. Plants.
8. Ice.
9. Debris.
10. Snow.
11. Water.
12. Dirt.
13. Foliage.
14. Pets
B. Dismantle, open, or uncover any system or component.
C. Enter or access any area which may, in the opinion of the
inspector, be unsafe.
D. Enter crawlspaces or other areas that are unsafe or not readily
accessible.
E. Inspect underground items such as, but not limited to,
underground storage tanks or other indications of their presence,
whether abandoned or actively used.
F. Do anything which, in the inspector's opinion, is likely to be
unsafe or dangerous to the inspector or others or damage property,
such as, but not limited to, walking on roof surfaces, climbing
ladders, entering attic spaces or negotiating with pets.
G. Inspect decorative items.
H. Inspect common elements or areas in multi-unit housing.
I. Inspect intercoms, speaker systems, radio-controlled, security
devices or lawn irrigation systems.
J. Offer guarantees or warranties.
K. Offer or perform any engineering services.
L. Offer or perform any trade or professional service other than
home inspection.
M. Research the history of the property, report on its potential for
alteration, modification, extendibility, or its suitability for a
specific or proposed use for occupancy.
N. Determine the age of construction or installation of any system
structure or component of a building, or differentiate between
original construction and subsequent additions, improvements,
renovations or replacements.
O. Determine the insurability of a property.
P. Perform or offer Phase 1 environmental audits.
Q. Inspect on any system or component which is not included in these
standards.
4. Glossary of Terms
4.1. Accessible: Can be approached or entered by the inspector
safely, without difficulty, fear or danger.
4.2. Activate: To turn on, supply power, or enable systems,
equipment, or devices to become active by normal operating controls.
Examples include turning on the gas or water supply valves to the
fixtures and appliances and activating electrical breakers or fuses.
4.3. Adversely Affect: To constitute, or potentially constitute, a
negative or destructive impact.
4.4. Alarm System: Warning devices, installed or free-standing,
including but not limited to: carbon monoxide detectors, flue gas
and other spillage detectors, security equipment, ejector pumps and
smoke alarms.
4.5. Appliance: A household device operated by use of electricity or
gas. Not included in this definition are components covered under
central heating, central cooling or plumbing.
4.6. Architectural Service: Any practice involving the art and
science of building design for construction of any structure or
grouping of structures and the use of space within and surrounding
the structures or the design, design development, preparation of
construction contract documents, and administration of the
construction contract.
4.7. Component: A permanently installed or attached fixture, element
or part of a system.
4.8. Condition: The visible and conspicuous state of being of an
object.
4.9. Crawlspace: The area within the confines of the foundation and
between the ground and the underside of the lowest floor structural
component.
4.10. Decorative: Ornamental; not required for the operation of
essential systems and components of a home.
4.11. Describe: To report in writing a system or component by its
type, or other observed characteristics, to distinguish it from
other components used for the same purpose.
4.12. Determine: To arrive at an opinion or conclusion pursuant to
examination.
4.13. Dismantle: To open, take apart or remove any component, device
or piece that would not typically be opened, taken apart or removed
by an ordinary occupant.
4.14. Engineering Service: Any professional service or creative work
requiring engineering education, training, and experience and the
application of special knowledge of the mathematical, physical and
engineering sciences to such professional service or creative work
as consultation, investigation, evaluation, planning, design and
supervision of construction for the purpose of assuring compliance
with the specifications and design, in conjunction with structures,
buildings, machines, equipment, works or processes.
4.15. Enter: To go into an area to observe visible components.
4.16. Evaluate: To assess the systems, structures or components of a
dwelling.
4.17. Examine: To visually look. See Inspect.
4.18. Foundation: The base upon which the structure or wall rests;
usually masonry, concrete, or stone, and generally partially
underground.
4.19. Function: The action for which an item, component, or system
is specially fitted or used or for which an item, component or
system exists; to be in action or perform a task.
4.20. Functional: Performing, or able to perform, a function.
4.21. Home Inspection: The process by which an inspector visually
examines the readily accessible systems and components of a home and
operates those systems and components utilizing these Standards of
Practice as a guideline.
4.22. Household Appliances: Kitchen and laundry appliances, room air
conditioners, and similar appliances.
4.23. Inspect: To visually look at readily accessible systems and
components safely, using normal operating controls and accessing
readily accessible panels and areas in accordance with these
Standards of Practice.
4.24. Inspected Property: The readily accessible areas of the
buildings, site, items, components, and systems included in the
inspection.
4.25. Inspector: One who performs a real estate inspection.
4.26. Installed: Attached or connected such that the installed item
requires tool for removal.
4.27. Material Defect: A condition of a residential real property or
any portion of it that would have a significant adverse impact on
the value of the real property or that involves an unreasonable risk
to people on the property. The fact that a structural element,
system or subsystem is near, at or beyond the end of the normal
useful life of such a structural element, system or subsystem is not
by itself a material defect.
4.28. Normal Operating Controls: Devices such as thermostats that
would be operated by ordinary occupants which require no specialized
skill or knowledge.
4.29. Observe: To see through visually directed attention.
4.30. Operate: To cause systems to function or turn on with normal
operating controls.
4.31. Readily Accessible: An item or component is readily accessible
if, in the judgment of the inspector, it is capable of being safely
observed without the removal of obstacles, detachment or
disengagement of connecting or securing devices, or other unsafe or
difficult procedures to gain access.
4.32. Recreational Facilities: Spas, saunas, steam baths, swimming
pools, tennis courts, playground equipment, and other exercise,
entertainment or athletic facilities.
4.33. Report: A written communication (possibly including images) of
any material defects seen during the inspection.
4.34. Representative Number: A sufficient number to serve as a
typical or characteristic example of the item(s) inspected.
4.35. Safety Glazing: Tempered glass, laminated glass, or rigid
plastic.
4.36. Shut Down: Turned off, unplugged, inactive, not in service,
not operational, etc.
4.37. Structural Component: A component which supports non-variable
forces or weights (dead loads) and variable forces or weights (live
loads).
4.38. System: An assembly of various components which function as a
whole.
4.39. Technically Exhaustive: A comprehensive and detailed
examination beyond the scope of a real estate home inspection which
would involve or include, but would not be limited to: dismantling,
specialized knowledge or training, special equipment, measurements,
calculations, testing, research, analysis or other means.
4.40. Unsafe: A condition in a system or component which is judged
to be a significant risk of personal injury during normal,
day-to-day use. The risk may be due to damage, deterioration,
improper installation or a change in accepted residential
construction standards.
4.41. Verify: To confirm or substantiate. |